The Deep One-Secondary Circuit Fusion System is an innovative high-tech product that integrates traditional secondary circuit protection with primary circuit control. By leveraging advanced digital technology and intelligent algorithms, this system combines the management, monitoring, and protection functions of primary and secondary circuits. It not only enhances the operational efficiency and reliability of the power system but also reduces system failure rates and operational costs. This product goes beyond the functionality of traditional circuit breakers and has optimized and innovated aspects such as protection, control, and isolation, providing strong support for the stable operation of the power system.

    PRODUCT PARAMETERS

    Item

    Unit

    Parameter

    Rated voltage

    kV

    12

    40.5

    Rated current

    A

    630

    1250

    Rated frequency

    Hz

    50

    50

    Rated peak withstand current

    kA

    50

    63

    Rated short-time withstand current

    kA

    20

    25

    Rated short-time withstand current duration

    S

    4

    4

    Rated active load breaking current

    A

    630

    1250

    Rated closed loop breaking time

    A

    630

    1250

    Rated cable charging breaking current

    A

    10

    10

    5% at rated active load breaking current

    A

    31.5

    63

    Rated no-load transformer breaking current rated capacity

    kVA

    1250

    1250

    Rated short-circuit closing current

    kA

    50

    63

    The main circuit of electronic

    μΩ

    ≤150

    ≤100

    1min power frequency withstand voltage(RMS)

    Dry test

    Between poles and poles to the ground

    kV

    42

    95

    Wet test

    Isolating fracture

    kV

    48

    110

    Between poles and poles to the ground

    kV

    30

    85

    Lightning impulse

    Between poles and poles to the ground

    kV

    75

    185

    withstand voltage (peak)

    Isolating fracture

    kV

    85

    215

    Mechanical life

    Times

    10000

    10000

    jiubaeg

    Product Features

    Deep One-Secondary Circuit Integration

    The system integrates traditional electrical protection and control functions with modern intelligent monitoring and data collection functions through digital technology and intelligent algorithms. This allows the power system to be monitored and protected in real-time on a single platform, reducing system complexity while enhancing operational efficiency and responsiveness.

    Multi-Dimensional Intelligent Protection

    The system adopts advanced intelligent protection algorithms that dynamically adjust protection strategies based on the real-time operating status of the power system. It includes multiple protection functions such as overload, short circuit, ground fault, over-voltage, under-voltage, and leakage, ensuring that the power system can rapidly disconnect fault currents and prevent equipment damage and downtime.

    Real-Time Monitoring and Remote Management

    The Deep One-Secondary Circuit Fusion System is equipped with powerful remote monitoring capabilities. Through communication protocols such as Modbus RTU and IEC 61850, it can transmit device status, fault alarms, and data to a central monitoring platform in real-time. Maintenance personnel can remotely check device status, diagnose faults, adjust parameters, and control operations, greatly improving maintenance efficiency and accuracy.

    Efficient System Optimization and Fault Diagnosis

    The system features intelligent fault diagnosis and early warning capabilities, using big data analysis to predict potential system failures and make adjustments or issue warnings in advance, thus reducing the occurrence of faults. When faults do occur, the system can accurately locate the problem area and respond quickly, minimizing downtime and improving equipment availability.

    Modular Design and Flexible Expansion

    The system adopts a modular design, making installation, expansion, and maintenance more convenient. Users can customize required functional modules according to the actual needs of the power system and configure them flexibly based on system expansion requirements. The modular structure not only improves system adaptability but also facilitates easier future maintenance and upgrades.

    High Reliability and Safety

    The product uses high-quality electrical components that are resistant to high temperatures, electromagnetic interference, and harsh environments. With an IP65 protection rating, the system is capable of resisting dust, water vapor, and other environmental factors, ensuring long-term stable operation.

    Energy Efficiency and Environmental Protection

    The Deep One-Secondary Circuit Fusion System optimizes power distribution and has intelligent scheduling capabilities that automatically adjust operational parameters according to changes in the grid load. This maximizes energy utilization, reduces energy waste, and contributes to environmental protection.

    Technical Specifications

    Operating Voltage: AC 220V ~ 400V (suitable for high-voltage grids)

    Protection Functions: Overload protection, short circuit protection, leakage protection, ground fault protection, over-voltage protection, under-voltage protection, etc.

    Monitoring Mode: Supports remote monitoring via WEB and APP

    Communication Protocol: Modbus RTU / TCP, IEC 61850, DNP3, etc.

    Protection Rating: IP65, dustproof and waterproof

    Operating Temperature: -20℃ ~ 70℃

    Service Life: Over 10 years

    System Interface: Customizable interfaces to meet different power system requirements

    Contact Information

    For more details, please contact us:

    Company Name: KENJING GROUP Co., Ltd.

    Phone: +86-15888718229

    Email: john@china-kenjing.com

    Leave Your Message

    Your Name*

    Phone Number

    Country

    Message*